**以前のリビジョンの文書です**
smartctl
- 前提
- Solaris系のS.M.A.R.TはATAコマンド叩けない。
- AHCIならできる。IDE互換だと無理。諦めましょう。
- smartctlのコンパイル
- <code># pkg install gcc-dev # wget http://sourceforge.net/projects/smartmontools/files/smartmontools/5.40/smartmontools-5.40.tar.gz/download # tar zxvf smartmontools-5.40.tar.gz # cd smartmontools-5.40 # ./configure && make # make install</code>
- 検索したら引っかかった人。
- SASカードであるところのBR10iにぶら下がっているHDDに向けて使ってみる。
- -T permissive つけた方が表示速度的に良いかも。
- <code># ./smartctl -T permissive -s on /dev/rdsk/c3t1d0p0 # ./smartctl -a /dev/rdsk/c3t1d0p0 smartctl 5.40 2010-10-16 r3189 [i386-pc-solaris2.11] (local build) Copyright (C) 2002-10 by Bruce Allen, http://smartmontools.sourceforge.net
START OF INFORMATION SECTION
Model Family: Hitachi Travelstar 7K500 Device Model: Hitachi HTS725050A9A364 Serial Number: 101207PCK404GLG45G5J Firmware Version: PC4OC70E User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 6 Local Time is: Sun Feb 6 15:15:43 2011 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled
Error SMART Thresholds Read failed: I/O error Smartctl: SMART Read Thresholds failed.
START OF READ SMART DATA SECTION
SMART overall-health self-assessment test result: PASSED
General SMART Values: Offline data collection status: (0x00) Offline data collection activity
was never started. Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever been run.
Total time to complete Offline data collection: ( 645) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode. Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 131) minutes. SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported.
SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTENAME FLAG VALUE WORST THRESH TYPE UPDATED WHENFAILED RAWVALUE 1 RawReadErrorRate 0x000b 100 100 062 Pre-fail Always - 0
2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0 3 Spin_Up_Time 0x0007 100 100 033 Pre-fail Always - 2 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 3 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 --- Pre-fail Offline - 0 9 Power_On_Hours 0x0012 100 100 --- Old_age Always - 0
10 SpinRetryCount 0x0013 100 100 —
Pre-fail Always - 0
12 PowerCycleCount 0x0032 100 100 —
Old_age Always - 3
191 G-SenseErrorRate 0x000a 100 100 —
Old_age Always - 0
192 Power-OffRetractCount 0x0032 100 100 —
Old_age Always - 1
193 LoadCycleCount 0x0012 100 100 —
Old_age Always - 16
194 TemperatureCelsius 0x0002 229 229 — Oldage Always - 24 (Min/Max 22/27) 196 ReallocatedEventCount 0x0032 100 100 —
Old_age Always - 0
197 CurrentPendingSector 0x0022 100 100 —
Old_age Always - 0
198 OfflineUncorrectable 0x0008 100 100 — Oldage Offline - 0 199 UDMACRCErrorCount 0x000a 200 200 — Oldage Always - 0 223 LoadRetryCount 0x000a 100 100 —
Old_age Always - 0
SMART Error Log Version: 1 No Errors Logged
SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1 SPAN MINLBA MAXLBA CURRENTTESTSTATUS
1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.</code>